Upright Sprinkler is a small, thermosensitive, glass-bulb spray sprinkler available in several different finishes and temperature ratings to meet design requirements.
Pendent Sprinkler is a small, thermosensitive, glass-bulb spray sprinkler available in several different finishes and temperature ratings to meet design requirements.
Conventional Pendent and Upright Sprinkler is a small, thermosensitive, glass-bulb spray sprinkler available in several different finishes and temperature ratings to meet design requirements.
Sidewall sprinkler head from another type. These small plates rest between the sprinkler’s orifice and the space it protects, shaping the water pattern as it sprays.
Pendent Concealed Sprinklers are thermo-sensitive glass bulb sprinklers having decorative flat cover plate designed to conceal the sprinkler for smooth ceilings.
The Inspector’s Test and Drain valve is designed to have two functions, both as an express drain and a test function for a wet sprinkler system.
Water flow detector designed to detect fire sprinkler activations and send an alarm to a fire alarm panel and/or local fire authorities when water flows through fire system piping.
The alarm check valve is a water flow alarm device designed for vertical installation in the main supply to a wet pipe sprinkler system.
A Zone Control Valve is a switch that is part of the water supply/fire protection system in a building, which includes landing valves, water storage tanks, and sprinkler systems.
FIFFCO UL Listed Supervisory Switch Butterfly Valves are produced for separating the zones and acting like control valves.
The devices that are used for measuring pressure are called pressure gauges. Gauge pressure is the pressure relative to atmospheric pressure.
The FIFFCO Flexible Sprinkler Hose is a unique sprinkler drop assembly comprised of a branch line adapter nipple
The Recessed Escutcheon Plate is designed for recessed installation with certain pendent and horizontal sidewall sprinklers.
Firefighting pipes are one of the most crucial components of any establishment. It protects occupants, assets, and other valuables in case of fire.
Fire sprinkler pipes and related fittings are generally made of carbon steel or ductile iron material and used to carry water or other liquid to connect firefighting equipment.
Sprinkler System Components & Accessories are the backbone of any reliable fire suppression network. FIFFCO GLOBAL LTD supplies certified, high-performance components — available in both Standard/Certified lines and Globally UL Listed lines — engineered for MEP projects, safety consultants, and procurement teams. Our product range carries UL Listed, FM Approved, KITEMARK, LPCB, VDS and CE (where applicable) certifications, meets NFPA compliance, and comes with a 5-year warranty and extreme temperature resilience for dependable service in demanding environments.
FIFFCO products are designed and manufactured to meet the exacting demands of modern fire protection systems:
FIFFCO covers every component you need — explained clearly so engineers can specify with confidence.
FIFFCO sprinkler components are specified across a wide range of industries and environments:
Q1: What is a sprinkler system component and why is specification important?
A1: A sprinkler system component is any part required to detect, actuate, deliver and control water for fire suppression (sprinkler heads, valves, detectors, gauges, piping). Correct specification ensures NFPA compliance, system reliability, and life-safety performance under design conditions.
Q2: What’s the difference between Standard/Certified and UL Listed lines?
A2: Standard/Certified lines meet recognized regional standards and may carry CE, KITEMARK, LPCB or VDS marks. UL Listed lines have been tested and listed by Underwriters Laboratories for global acceptance — choose UL Listed where project specs or authorities require it.
Q3: How often should I test and maintain components like test & drain valves, water flow detectors and wet alarm check valves?
A3: Follow NFPA maintenance schedules: quarterly visual checks, semi-annual functional tests for alarms/valves, and annual full inspections by qualified technicians. Components should be serviced immediately after activation or any abnormal reading.
Q4: Are FIFFCO sprinkler components compatible with existing networks and pipe fittings?
A4: Yes. FIFFCO parts are engineered for compatibility with common piping standards and fittings; flexible sprinkler hose options and standardised connection sizes simplify retrofits and new installs.
FIFFCO delivers a complete, certified portfolio of Sprinkler System Components & Accessories engineered for performance, safety, and ease of installation. From upright and pendent sprinkler heads to zone control valves, water flow detectors and pipe fittings — every component is built to meet stringent standards and real site conditions. Ensure total safety with FIFFCO. Contact us today for a quote on our Sprinkler System & Accessories.